12V/24W DoE VI Fixed Pin Adapter

12V/24W DoE VI Fixed Pin Adapter

The 12V/0.5A adaptor series is the latest offering from a world leader in charging adapter technology and manufacturing - HHY Technology. The 12V/2A value adaptor series are designed to work with most 12V powered networking communication devices, such as Router, Switch, Set-Top Box (STB) and...

Product Details

The 12V/0.5A adaptor series is the latest offering from a world leader in charging adapter technology and manufacturing - HHY Technology. The 12V/2A value adaptor series are designed to work with most 12V powered networking communication devices, such as Router, Switch, Set-Top Box (STB) and other 12V powered devices.


Features:Electrical Specifications:
Model No.CC00309
EfficiencyDoE Level VI & CoC V5 Tier 2 (86.2%)Input Voltage100~240Vac (90~264Vac min/max)
Power Saving<0.075W @ no load, 115Vac & 230VacFrequency50/60Hz Nom (47~63Hz min/max)
ProtectionOVP (20V), OCP (4A), SCPInput Current0.6A (RMS) max @ 100Vac
Turn-On Delay Time<3 sec at min/max AC power onOutput Voltage12V,
Hold-up Time>10mS@max load,115Vac/60Hz & 230Vac/50HzOutput Current2A
Rise Time<100mS @ max load, 120Vac/60HzMaximum Output Power24W continuous
Fall Time<50mS @ max load, 120Vac/60HzOutput Ripple & Noise240mV (pk-pk) @25℃ and 115 & 230Vac
Dynamic Response±10% max, @ 90~264Vac, 25℃Line Regulation±5%
Rise rate = 0.5A/us, Fall rate = 0.5A/usLeakage Current<0.25mA max @ 100Vac & 240Vac
(Load transient: 20%  80%  20%)Inrush Current<40A max @ 115Vac/60Hz, 25℃, Max load
Thigh = 1mS, Tlow = 1mS<80A max @ 230Vac/50Hz, 25℃, Max load
IsolationPrimary to Secondary 3000Vac, 10mA for 1min.Capacitive Load3300uF @ Von=2V (CC mode), 100~240Vac
InsulationPrimary to Secondary >10MΩ 500Vdc
DimensionUS : 83.5*53.5*35 (mm)



Environmental Specifications:Safety and Compliance:
Operating Temperature0℃ ~ +40℃UL/cUL 60950-1 approved
Storage Temperature-20℃ ~ +70℃EMI: EN55022 & CISPR 22 class B, FCC class B
Humidity0% ~ 90%ESD : Air ±15KV, Contact: ±8KV E61000-4-2, Criteria B
E Cap Life10,000 Hrs. min @ 100Vac, 80% load, 40℃Surge: ±1kV (L-L), ±2kV (L-G), EN61000-4-5, Criteria B
MTBF400K Hrs min. @100Vac, Full load, 40℃RS: EN61000-4-3, Criteria A
(Telcordia SR-332, issue 2)EFT/B: EN61000-4-4, Criteria B
UL/cUL 60950-1 approvedCS: EN61000-4-6, Criteria A
EMI:EN55022 & CISPR 22 class B, FCC class BPFMF: EN61000-4-8, Criteria A
ESD :Air ±15KV, Contact: ±8KV E61000-4-2, Criteria BVoltage Dip: EN61000-4-11, Criteria B, C
Surge:±1kV (L-L), ±2kV (L-G), EN61000-4-5, Criteria B
RS:EN61000-4-3, Criteria A
EFT/B:EN61000-4-4, Criteria
Previous:12V/60W DoE VI Fixed Pin Adapter Next:12V/36W DoE VI Fixed Pin Adapter

Inquiry